Opentrons Help Center
Help from the Opentrons Team
Search results for:
calibration
Calibrating
labware FAQ
If you
calibrate
labware in one slot that
calibration
data is applied to all slots that labware exists… What is labware
calibration
? Why should you do it?… When should you
calibrate
labware?
M
Written by
Morgan
Updated over a week ago
OT-One:
Calibrating
the Pipettes
Once your labware is
calibrated
and saved on your deck, you'll need to
calibrate
your pipettes so that… Also, make sure your pipette is correctly installed on your robot before attempting to
calibrate
… When
calibrating
pipettes, you'll save four positions: Top, Bottom, Blow Out and Drop Tip
Written by
Ethan Jones
Updated over a week ago
OT-One:
Calibrating
the Deck
Once all of your labware containers are
calibrated
, make sure to also
calibrate
your pipette(s)!… Each of these needs to be
calibrated
before your protocol can run… The list is populated based on which container you should
calibrate
first
O
Written by
Opentrons
Updated over a week ago
OT-One: X & Y Belt
Calibration
As a standard maintenance procedure run the X & Y belt
calibration
to keep your machine The X & Y… belt
calibration
zip file contains binary files for both Mac and Windows operating systems… Step 3: Unzip the file Step 4: Open the folder with the
calibration
files Step 5: Run the
O
Written by
Opentrons
Updated over a week ago
Get started:
Calibrate
the deck
Find the Robot
Calibration
>
Calibrate
deck section. Select the
Calibrate
button… Deck
calibration
is one important part your OT-2's positional
calibration
, which is what makes sure it… Continue:
Calibrate
tip length and pipette offset Learn more: How positional
calibration
works on the
Written by
Max Marrone
Updated over a week ago
Protocol Designer: There are pipettes or no labware to
calibrate
when I try to run a protocol
M
Written by
Morgan
Updated over a week ago
Calibration
best practices
Pipette
Calibration
Labware
Calibration
It is important to be mindful during pipette attachment… There are two
calibration
processes that require manual tip attachment: deck
calibration
and pipette… Cancelling pipette
calibration
Written by
Ojas Patel
Updated over a week ago
Troubleshooting
calibration
issues
There are two types of issues related to
calibration
: technical issues that block the
calibration
processes… Complete a factory reset of pipette
calibration
and retry pipette
calibration
2… Pipette
calibration
failure
Written by
Ojas Patel
Updated over a week ago
OT-One: How to access the
calibration
file
The easiest way to access the
calibration
file is to open the containers folder first… folder From this folder, you will need to navigate backwards in the file path one level to find the
calibrations
Written by
Ethan Jones
Updated over a week ago
Get started:
Calibrate
labware
From the Protocol tab, select the
Calibrate
tab or the Proceed to
calibrate
button: Depending on… (To learn more, check out How
calibration
works on the OT-2.)… Labware
calibration
is meant for small adjustments
Written by
Ethan Jones
Updated over a week ago